Now you can view the application note ...

Thank you for requesting a copy of the Thermo Fisher application note titled 'Monoclonal Antibody Mass Confirmation using Intact Protein Deconvolution for a Compliance-ready Manufacturing Environment'. To download your own personal copy simply click on the button below.

Download Thermo Fisher Application Note >>

 

 Related Resources

Document_Web[Application Note] Biosimilar Sequence Variant Assessment and Product Quality Attribute Monitoring
The Thermo Scientific™ HR-MAM workflow for biosimilarity assessment is evaluated. The workflow was used to compare rituximab drug product (DP) with an investigational biosimilar produced in NIBRT’s laboratories (BS).

Document_Web[Application Note] GC HRAM Validated Method for the Rapid Determination of 15 Nitrosamines in Metformin
Separation of 15 nitrosamines was achieved in under 14 minutes with LOQs <2 ng/g (ppb w/w) validated to ICH regulatory guidelines and easily meeting FDA LOQ requirements of 30 ppb.

Document_Web[Application Note] HRAM LC-MS Method for the Determination of Nitrosamine Impurities in Drugs
This note demonstrates the detection and quantification of nine nitrosamines in ranitidine with a single liquid chromatography-high resolution accurate mass (HRAM) mass spectrometry method.

Document_Web[Application Note] Overcoming Strong Solvent Effects during Method Transfer of a Compendial Method for the Analysis of Hesperidin
IThis note demonstrates the use of the Thermo Scientific™ Vanquish™ Core HPLC System equipped with a strong solvent loop to mitigate strong sample solvent effects occurring in a compendial method.

Document_Web[Application Note] Improving Targeted Peptide Quantification
In this application note we discuss characterization and accurate quantification of proteins in complex matrices for the pharma/biopharma sector for use in PKPD, discovery, regulated bioanalysis, and therapeutic drug research.

Document_Web[Application Note] Quality Control of Oligonucleotides with a Single Quadrupole Mass Spectrometer
This note discusses the benefit of mass spectrometric analysis with a single quadrupole mass detector for oligonucleotide quality control.

Document_Web[Application Note] Increasing Throughput of Native SEC-MS in Biopharmaceutical Development using a Tandem UHPLC Setup
Obtaining protein aggregation and intact MS product quality attributes simultaneously with excellent platform robustness and reduction of analysis time per sample with tandem analysis utilizing Thermo Scientific Vanquish Duo UHPLC.

Document_Web[Application Note] Determination of Nitrite Impurity in Dalteparin Sodium using Ion Chromatography
This application note demonstrates how the USP Dalteparin Sodium monograph for nitrite impurity method can be executed with a Thermo Scientific™ Dionex™ IonPac™ AS15 column using an ion chromatography system.

Document_Web[Application Note] Forced-degradation Evaluation of Erythromycin by HPLC and Single Quadrupole Mass Spectrometry
This application note discusses the development of a simple, stability-indicating LC-MS method for erythromycin and compares the impurity profiles of an erythromycin reference standard with stressed analyte.

Document_Web[Application Note] Analysis of Cefprozil and Related Impurities by Reversed-phase Liquid Chromatography with UV Detection
The quantification of cefprozil-related impurities based on the Ph. Eur. method is easily performed with high precision utilizing a new robust HPLC system built for the routine pharma analytical labs.

Document_Web[Application Note] A Global pH-gradient Based Charge Variant Analysis Directly Coupled to HRAM-MS (CVA-MS) for mAb Analysis
This application note describes how to achieve high information content with no sample preparation using charge variant separation coupled to high resolution mass spectrometry for the simultaneous quantification of multiple mAb critical quality attributes.

Document_Web[Application Note] Identity Confirmation and Accurate Quantitation of a Genotoxic Impurity in an Active Pharmaceutical Ingredient by UHPLC-UV coupled to a Single Quadrupole Mass Detector
The combination of UV and a single quadrupole mass detector is a powerful tool for API analysis in early stages of development, enabling confirmation of expected impurities.

Document_Web[Application Note] Doubling Chromatographic Throughput using Dual LC
The Thermo Scientific Vanquish Duo system for Dual LC enables two sample runs concurrently, so samples to run in half the time, improving pharmaceutical drug analysis.

Document_Web[Application Note] Simultaneous Liquid Chromatographic Analysis of Acetaminophen Impurities
This application note demonstrates the capabilities for Dual LC to run independent HPLC and UHPLC methods simultaneously using one instrument.

Document_Web[Application Note] Transfer of an EP Method for Mebendazole from a Waters Acquity UPLC System to a Vanquish Horizon UHPLC System
This note will discuss the transfer of analytical HPLC methods from a Waters Acquity UPLC system to the Vanquish platform and highlight the impact of column thermostatting.

Document_Web[Application Note] Determination of Genotoxic Nitrosamines in Valsartan with Gas Chromatography and Mass Spectrometry
This application note provides an evaluation of the quantitative performance of the Thermo Scientific™ TriPlus™ 500 Gas Chromatography Headspace Autosampler for determination of genotoxic nitrosamines in Valsartan according to the Chinese Pharmacopoeia method and US FDA recommended methodology.

Document_Web[Application Note] Routine-grade Performance of a New Static Headspace Autosampler for The Analysis of Residual Solvents according to USP <467> Method
This application note evaluates the performance of the Thermo Scientific™ TriPlus™ 500 Gas Chromatography Headspace Autosampler for the determination of residual solvent content in water-soluble and water-insoluble pharmaceuticals according to the United States Pharmacopeia <467> method.

 

Document_Web[Application Note] Method Transfer of a USP Derived Acetaminophen Assay
This application note demonstrates the transfer of analytical HPLC methods from an Agilent™ 1260 Infinity system to the Thermo Scientific™ UltiMate™ 3000 and the Thermo Scientific™ Vanquish™ platforms.

 

Document_Web[Application Note] An Automated High-throughput Workflow for Peptide Mapping to Monitor Post-translational Modifications (PTMs) of Monoclonal Antibodies
This application note demonstrates the benefits of automated high-throughput trypsin digestion for highly reproducible peptide mapping of monoclonal antibodies using the Thermo Scientific™ SMART Digest™ Kit on the Thermo Scientific™ KingFisher™ Duo Prime purification system.

 

Document_Web[Application Note] Simultaneous Analysis of Monoclonal Antibodies using a Novel Dual-channel UHPLC Instrument and Orthogonal Chromatography
The Vanquish Duo system for Dual LC uses separate inject values and sample loops, analysing two samples simultaneously, allowing the same number of samples to run in half the time.

 

Document_Web[Compendium] Trace Elemental Analysis of Pharmaceutical Products
This compendium provides detailed methods for the analysis of trace elements in pharmaceutical products using AAS, ICP-OES and ICP-MS covered by the NEW USP chapters 232 and 233.

Document_Web[Application Note] Doubling Chromatographic Throughput using Dual LC for Pharmaceutical Analysis
The Thermo Scientific Vanquish Duo system for Dual LC enables the analysis of two samples simultaneously, allowing the same number of samples to run in half the time.


Document_Web[Application Note] Analysis of Ethyl Glucuronide and Ethyl Sulfate in Urine with TSQ Quantis MS
This application note demonstrates how the TSQ Quantis triple quadrupole mass spectrometer provides superb sensitivity and robustness for the analysis of EtG and EtS in urine.

 

Document_Web.png[Application Note] Testing Robustness: Immunosuppressant Drugs in Blood with a TSQ Quantis MS
The TSQ Quantis MS gives reproducible results on a robust platform suitable for analysis of immunosuppressant drugs in blood for clinical research.

 

Document_Web.png[Application Note] A Sensitive and Efficient Method to Analyse THC and THCCOOH in Oral Fluid Using LC-MS/MS in Forensic Toxicology Laboratories
A sensitive and efficient LC-MS/MS method is demonstrated for simultaneous quantification of THCCOOH and THC, extracted from oral fluid, in forensic toxicology laboratories.

 

Document_Web.png[Application Note] A Novel 75 cm Column Size Gives Increased Resolution and Better Sequence Coverage
The separation of complex peptide mixtures and their subsequent identification is crucial in the field of bottom-up proteomics. The increased peak capacity of the 75 cm column leads to enhanced quality of the separation, even when using similar gradients. Using even longer gradients can further improves results. The use of the Thermo Scientific™ EASY-Spray™ C18, 75 cm column offers improved peak capacity and higher sensitivity allowing enhanced sequence coverage, which is critical for better protein identification.